amp3.cfg

This file contains all configuration data for this optimization. Of special interest is the following section, which sets the required measurements and the constraints on the measured parameters:

# Measurements #

ac_power:VDD:MIN:0

dc_gain:VOUT:GE:122

unity_gain_frequency:VOUT:GE:3.15E6

phase_margin:VOUT:GE:51.8

phase_margin:VOUT:LE:70

amp3_slew_rate:VOUT:GE:0.777E6

#

Each of these entries is linked to a file in the /extract subdirectory, having exactly the same names as given here, e.g. ac_power, dc_gain, unity_gain, phase_margin, and amp3_slew_rate. Each of these files contains an # Info # section, which is currently not used. The # Commands # section may contain a measurement command (including ASCO parameter #SYMBOL#, see file /extract/unity_gain_frequency). It also may contain a .control section (see file /extract/phase_margin_min). During set-up #SYMBOL# is replaced by the file name, a leading `z', and a trailing number according to the above sequence, starting with 0.